High friction grip bolts are commonly used in strutural steel works. They normally consist of high tensile strength bolts and nuts with washers. The bolts are tightened to a shank tension so that the transverse load across the joint is resisted by the friction between the plated rather than the bolts shanks shear strength.
this is some of FIDIC clauses and actions required by contractor and employee Clause no Clause Action by Action 1.9 Delayed drawings Contractor - Give notice to engineer -EOT+ cost+ profit 1.13 Compliance with laws Employer To give all required permits and licenses Contractor For delayed permits : EOT+ cost+ profit 1.6 Contract agreement Employer Within 35 day after letter of acceptance 2.1 Right of access to the site Employer Contractor If delayed EOT+ cost+ profit 2.4 Employers financial arrangement employer Give notice to the contractor when 1-variation >10% or sum of all variations >30% 2- doesn’t receive p...